RU EN

DVA144.XXX vibration velocity sensors with digital output

DVA144.XXX vibration velocity sensors with digital output

Designed for measurement of the root-mean square (RMS) value of vibration velocity in emergency protection systems (EPS);

Consist of a sealed housing, which are integrated acceleration sensor and conversion board;

Sensor versions:

  • DVA144.104 - triangular case, all-in-one cable connection, 3-screw mount;
  • DVA144.164 - triangular case, TIK-KXX connector on cable, mount for 3 screws;
  • DVA144.214 - cylindrical small-sized housing, TIK-KXX connector on the body (analogue of MIL-C-5015), mounting on a stud;
  • DVA144.714 - rectangular case, TIK-KXX connector on the body (analogue of MIL-C-5015), 1 screw mount;

To install the sensor assembly DVA144.214 uses the standard stud M8 / M10 / M12; for the special order it is possible to supply the studs with any thread, including inch;  

DVA144.214 allows the use of cable assemblies with MIL connector from imported sensors

Output signal type – RS-485 (Modbus RTU) or RS-485 (Modbus RTU) + discrete output

Additional photos

Reviews

Related equipment

TIK-PLC 991
controller
Cable cutting tool

specifications

Metrological parameters

  • Conversion coefficient, mA*s/mm / Range of indications of RMS vibration velocity, mm/s
    1 / 0-10
    1 / 0-12.7
    1 / 0-20
    1 / 0-25
    1 / 0-25.4
    1 / 0-30
    1 / 0-40
    1 / 0-50
    1 / 0-50.8
    1 / 0-60
    1 / 0-80
    1 / 0-100
  • Operating frequency range, Hz
    2-1000
    3-1000
    5-1000
    10-1000

Interface

  • Output signal type
    digital RS-485
    digital RS-485 + discrete output
  • Supply voltage range, V
    10-24
  • Protocol
    Modbus RTU

Explosion protection

  • Kind
    intrinsically safe circuit
  • Marking
    0Ex ia IIC T6...T2 Ga X / PO Ex ia I Ma X
    2Ex nA IIC T6...T2 Gc X
  • Connection
    through TIK-PLC 991 controller

Design parameters

  • Version
    all-in-one cable connection (DVA144.104)
    TIK-KXX connector on cable (DVA144.164)
    TIK-KXX connector on the body (analogue of MIL-C-5015) (DVA144.214, DVA144.714)
  • Overall dimensions, mm
    Ø39.25x43.5 (DVA144.104)
    Ø39.25x36 (DVA144.164)
    Ø26.5x57.5 (DVA144.214)
    39х54x24.5 (DVA144.714)
  • Weight, kg, not more than
    0.1 (DVA144.1XX)
    0.13 (DVA144.2XX)
    0.25 (DVA144.714)
  • Mounting type
    screw M4x21 (M4x28) 3 pcs. (DVA144.1XX)
    stud M8 / M10 / M12 1 pc. (DVA144.214)
    screw M6 1 pc. (DVA144.714)
  • Protection class
    IP65/IP68

Operating parameters

  • Operating temperature range, ºС
    -40...+80 (climatic version H)
    -60...+80 (climatic version X)
    -196...+80 (climatic version K)

Reliability parameters and manufacturer's guarantees

  • MTBF, hours, not less than
    100 000
  • Warranty service life, months
    24
  • Service life, years, not less than
    20
  • Time between verifications
    2 years
Service center