RU EN

IKV-1-4-1.1 vibration measuring channel

IKV-1-4-1.1 vibration measuring channel

Designed to measure speed (factory mode) and phase angle (set by jumper) in emergency protection systems (EPS)*;

It consists of a DS-x eddy-current transducer, an AS 141 converter (in a connection box), or an AS 1412 converter in a connector. Depending on the version, indication blocks are used to output the measured parameters;

Channel versions:

  • IKV-1-4-1.1 ver. A - DS-0 (DS-1, DS-2, DS-3) ver. 00 or 01 (with connector) eddy-current transducer, AS 141 converter, (connection box, TIK-BIS.121.0X0X safety barrier)**;
  • IKV-1-4-1.1 ver. B - DS-0 (DS-1, DS-2, DS-3) ver. 02 eddy-current transducer, AS 1412 converter in the socket, (connection box, TIK-BIS.121.0X0X safety barrier)**;
  • IKV-1-4-1.1 ver. V - DS-0 (DS-1, DS-2, DS-3) ver. 02 eddy-current transducer, AS 1412 converter in the socket, indication block, (connection box, TIK-BIS.121.0X0X safety barrier)**;
  • IKV-1-4-1.1 ver. E - DS-0 (DS-1, DS-2, DS-3) ver. 00 or 01 (with connector) eddy-current transducer, AS 141 converter (with display), (connection box, TIK-BIS.121.0X0X safety barrier)**.

Output signal type:

  • 4-20 mA (for ver. A, B, V, E);
  • 0-10 V (for ver. E);
  • digital output (for ver. E).

*By default, the channel is set to 40X metal

**Available as an option

Additional photos

Reviews

Related equipment

TIK-BIS
safety barriers

specifications

Metrological parameters

  • Range of measurement of frequency of rotation, rev/min
    0-16 000
  • Measurement cycle time, s
    0.0005
  • Installation gap (default), mm
    1.0±0.2 (eddy-current transducer DS-0)
    1.0±0.2 (eddy-current transducer DS-1)
    2.0±0.2 (eddy-current transducer DS-2)
    3.0±0.2 (eddy-current transducer DS-3)

Interface

  • Output signal type
    "current loop" 4-20 mA (for ver. A, B, V, E)
    0-10 V (for ver. E)
    digital output (for ver. E)
  • Supply voltage range, V
    10-24

Explosion protection

  • Kind
    intrinsically safe circuit
  • Marking
    0Ex ia IIC T6...T1 Ga X (DS-x eddy-current transducer)
    0Ex ia IIC T6...T1 Ga X (AS 1xx converter)
    0Ex ia IIC T6...T4 Ga X (connection box)
  • Connection
    through TIK-BIS safety barrier

Design parameters

  • Overall dimensions, mm
    D(6.8) L(50; 70; 90) (DS-0 eddy-current transducer)
    D(8.5) L(30; 50; 70; 90) (DS-1 eddy-current transducer)
    D (14.5) L(50; 70; 90) (DS-2 eddy-current transducer)
    D (22.5) L(90) (DS-3 eddy-current transducer)
    98.5x27.5x59 (AS 141 converter for ver. A)
    Ø30x66.5 (AS 1412 converter for ver. B, V)
    105x22.5x67 (AS 141 converter for ver. E)
    105x22.5x67 (indication block)
    277x254.5x83 (connection box for ver. A, B, E)
    304x224x108 (connection box for ver. V)
  • Weight, kg, not more than
    0.25 (DS-0, DS-1 ver. 00, 01 eddy-current transducer)
    0.35 (DS-0, DS-1 ver. 02 eddy-current transducer)
    0.3 (DS-2 ver. 00, 01 eddy-current transducer)
    0.4 (DS-2 ver. 02 eddy-current transducer)
    0.4 (DS-3 ver. 00, 01 eddy-current transducer)
    0.5 (DS-3 ver. 02 eddy-current transducer)
    0.1 (AS 141 / AS 1412 converter)
    0.1 (indication block)
    2.5 (connection box for ver. A, B, E)
    3.25 (connection box for ver. V)
  • Mounting type
    M8x1 threaded hole (DS-0 eddy-current transducer)
    M10x1 threaded hole (DS-1 eddy-current transducer)
    M16x1 threaded hole (DS-2 eddy-current transducer)
    M24x1 threaded hole (DS-3 eddy-current transducer)
  • Protection class
    IP65/IP68 (DS-x eddy-current transducer)
    IP20 (AS 1xx converter)
    IP20 (indication block)
    IP65/IP67 (connection box)

Operating parameters

  • Operating temperature range, ºС
    -40...+135 (DS-x ver. 00, 01 eddy-current transducer)
    -40...+70 (DS-x ver. 02 eddy-current transducer)
    -60...+135 (DS-x ver. 00, 01 eddy-current transducer, climatic version HL)
    -60...+70 (DS-x ver. 02 eddy-current transducer, climatic version HL)
    -40...+70 (AS converter)
    -60...+70 (AS converter, climatic version HL)

Reliability parameters and manufacturer's guarantees

  • MTBF, hours, not less than
    40 000
  • Warranty service life, months
    24
  • Service life, years, not less than
    10
  • Installed device life, hours, not less than
    80 000
  • Time between verifications
    1 year